Thermal science
Microchannel design, enhanced boiling surfaces, hotspot control, and temperature uniformity.
Advanced thermal management R&D company
Enthalux: Cooling Next-Generation AI Accelerators.
Enthalux develops high-performance single-phase cold plates, microjet dielectric phase-change systems, immersion evaporators, and rack-level cooling architectures for high-power chips and dense computing.
Company
Enthalux works at the intersection of heat transfer, microfluidics, mechanical integration, and deployment engineering. Our focus is practical cooling management for AI accelerators, GPUs, advanced packages, power devices, high-density servers, and data center infrastructure.
The company translates microchannel water-based single-phase cooling, microjet dielectric phase-change cold plates, immersion evaporators, and low-pressure two-phase systems into deployable product and system platforms. We collaborate with Sparkle and Intel to advance practical thermal solutions from component development through system-level integration.
Microchannel design, enhanced boiling surfaces, hotspot control, and temperature uniformity.
Cold plate geometry, vapor return, dielectric fluid handling, sealing, and compact integration.
Bench testing, closed-loop validation, pressure-drop evaluation, and server/rack architecture work.
Working across the technology ecosystem to accelerate practical cooling innovation.
Why it matters
AI training, inference, and HPC workloads keep increasing processor power and local heat flux.
Optimized single-phase loops serve demanding systems efficiently, while two-phase designs extend capacity for extreme heat flux.
Leakage risk, service interruption, and maintenance cost become major barriers at data center scale.
Cold plate capacity alone is not enough; thermal resistance, seals, pipes, joints, and rack loops matter.
Technologies
Our portfolio combines liquid-cooled microchannel cold plates and distribution systems with low-pressure dielectric phase-change technology. Each architecture is engineered around heat flux, temperature, pressure, reliability, serviceability, and facility conditions.
Low-boiling-point dielectric working fluid enters the engineered plate.
Internal micro-distributors feed microchannels across the heat source.
Micro-/nano-structures increase boiling heat transfer and uniformity.
Low-resistance passages route vapor-liquid return toward condensation.
Microchannel cold plates, manifolds, coolant distribution, and controls optimized for efficient, reliable heat removal.
6 kW-class single cold plate cooling for GPUs, AI accelerators, 3DIC packages, and power devices.
Liquid evaporators for immersion systems with high heat-flux chip and power-electronics loads.
Parallel cold plate connection, vapor-liquid return, centralized condensation, storage, and pumping.
Performance
| Category | Parameter | Value |
|---|---|---|
| Two-phase cold plate | Single plate cooling power | Over 6,000 W |
| Two-phase cold plate | Heat flux | Above 300 W/cm2 |
| Two-phase cold plate | Thermal resistance | Below 0.007 K/W |
| System | Operating pressure | Below 3 bar |
| System | Pressure drop | Below 20 kPa at 4000 W |
| Mechanical | Cold plate height | Below 20 mm |
| Immersion evaporator | Single-chip heat load | Above 3,000 W |
| Immersion evaporator | Heat flux | Above 130 W/cm2 |
Solution pathways
Enthalux selects the cooling path from chip heat flux, package geometry, pressure limits, server layout, facility conditions, and service requirements—not from a one-size-fits-all platform.
Single-phase microchannel cooling for GPUs, accelerators, 3DIC packages, and high-power devices.
Low-pressure dielectric phase-change cooling for concentrated hotspots and next-generation package power.
Compact evaporators that remove high local heat loads within dielectric immersion environments.
System architecture that carries component-level cooling performance through the server and rack.
Contact
Share the chip power map, package size, allowable pressure, coolant and facility conditions, target server form factor, and prototype timeline. The team supports customized cold plate design, prototype testing, and system-level verification.
ContactZhengduo Zhu
Phone (Australia)+61 451 778 535
Phone (China)+86 158 8967 6602