Liquid cooling hardware installed in a high-density AI server

Advanced thermal management R&D company

Enthalux: Cooling Next-Generation AI Accelerators.

Advanced liquid cooling for the AI compute era.

Enthalux develops high-performance single-phase cold plates, microjet dielectric phase-change systems, immersion evaporators, and rack-level cooling architectures for high-power chips and dense computing.

Company

An R&D company focused on cooling management for high-power electronics.

Enthalux works at the intersection of heat transfer, microfluidics, mechanical integration, and deployment engineering. Our focus is practical cooling management for AI accelerators, GPUs, advanced packages, power devices, high-density servers, and data center infrastructure.

The company translates microchannel water-based single-phase cooling, microjet dielectric phase-change cold plates, immersion evaporators, and low-pressure two-phase systems into deployable product and system platforms. We collaborate with Sparkle and Intel to advance practical thermal solutions from component development through system-level integration.

01

Thermal science

Microchannel design, enhanced boiling surfaces, hotspot control, and temperature uniformity.

02

Prototype engineering

Cold plate geometry, vapor return, dielectric fluid handling, sealing, and compact integration.

03

System verification

Bench testing, closed-loop validation, pressure-drop evaluation, and server/rack architecture work.

Collaborators

Working across the technology ecosystem to accelerate practical cooling innovation.

Sparkle Intel

Why it matters

AI and HPC systems need the right cooling architecture at every power level.

Higher chip power

AI training, inference, and HPC workloads keep increasing processor power and local heat flux.

Architecture selection

Optimized single-phase loops serve demanding systems efficiently, while two-phase designs extend capacity for extreme heat flux.

Reliability exposure

Leakage risk, service interruption, and maintenance cost become major barriers at data center scale.

System scalability

Cold plate capacity alone is not enough; thermal resistance, seals, pipes, joints, and rack loops matter.

Technologies

Single- and two-phase cooling engineered as complete systems.

Our portfolio combines liquid-cooled microchannel cold plates and distribution systems with low-pressure dielectric phase-change technology. Each architecture is engineered around heat flux, temperature, pressure, reliability, serviceability, and facility conditions.

Enthalux two-phase dielectric cold plate
01 Dielectric liquid inlet

Low-boiling-point dielectric working fluid enters the engineered plate.

02 Microjet distribution

Internal micro-distributors feed microchannels across the heat source.

03 Enhanced phase change

Micro-/nano-structures increase boiling heat transfer and uniformity.

04 Vapor outlet and return

Low-resistance passages route vapor-liquid return toward condensation.

Single-phase cooling systems

Microchannel cold plates, manifolds, coolant distribution, and controls optimized for efficient, reliable heat removal.

Direct-to-chip cold plates

6 kW-class single cold plate cooling for GPUs, AI accelerators, 3DIC packages, and power devices.

Immersion evaporators

Liquid evaporators for immersion systems with high heat-flux chip and power-electronics loads.

Rack cooling architecture

Parallel cold plate connection, vapor-liquid return, centralized condensation, storage, and pumping.

Performance

Reported prototype performance, displayed as engineering parameters.

Thermal load handling

reported prototype values
Immersion evaporator single-chip load
>3,000 W
Pressure-drop verification point
4,000 W
Two-phase cold plate capacity
>6,000 W
<0.007 K/W thermal resistance
<20 kPa pressure drop at 4000 W
<20 mm overall cold plate height
>130 W/cm2 immersion evaporator heat flux
Actual extracted parameters
Category Parameter Value
Two-phase cold plate Single plate cooling power Over 6,000 W
Two-phase cold plate Heat flux Above 300 W/cm2
Two-phase cold plate Thermal resistance Below 0.007 K/W
System Operating pressure Below 3 bar
System Pressure drop Below 20 kPa at 4000 W
Mechanical Cold plate height Below 20 mm
Immersion evaporator Single-chip heat load Above 3,000 W
Immersion evaporator Heat flux Above 130 W/cm2

Solution pathways

Match the cooling architecture to the thermal envelope.

Enthalux selects the cooling path from chip heat flux, package geometry, pressure limits, server layout, facility conditions, and service requirements—not from a one-size-fits-all platform.

01 Direct to chip

AI accelerator cold plates

Single-phase microchannel cooling for GPUs, accelerators, 3DIC packages, and high-power devices.

Best fit
High-power packages with established facility-water or CDU infrastructure.
Engineering scope
Cold plate, manifold, seals, pressure drop, and temperature-uniformity validation.
Discuss the chip envelope
02 Two phase

Extreme heat-flux cooling

Low-pressure dielectric phase-change cooling for concentrated hotspots and next-generation package power.

Best fit
Thermal envelopes that exceed practical single-phase flow, footprint, or pumping limits.
Engineering scope
Microjet distribution, enhanced boiling surface, vapor-liquid return, and condensation loop.
Review reported parameters
03 Immersion

Immersion evaporators

Compact evaporators that remove high local heat loads within dielectric immersion environments.

Best fit
Immersion servers where chip-level heat flux requires targeted phase-change enhancement.
Engineering scope
Evaporator geometry, fluid compatibility, mounting, vapor management, and bench testing.
Plan an immersion prototype
04 Rack scale

Dense server and rack integration

System architecture that carries component-level cooling performance through the server and rack.

Best fit
Multi-accelerator servers and dense racks requiring coordinated thermal and mechanical design.
Engineering scope
Parallel distribution, return routing, condensation, storage, pumping, and service access.
Define the rack architecture

Contact

Start a technical discussion with Enthalux.

Share the chip power map, package size, allowable pressure, coolant and facility conditions, target server form factor, and prototype timeline. The team supports customized cold plate design, prototype testing, and system-level verification.